Homes, offices and medical buildings around Lanham and Seabrook: get backflow assemblies tested and repaired.

Need a Lanham backflow test?
Call now to be connected with a local plumber in Lanham.
(202) 915-7612

Lanham is on WSSC Water, so its cross-connection rules apply: all testable backflow assemblies, including those on in-ground irrigation, some 2007 to 2009 home fire sprinkler systems and chemically treated boilers, are tested every year and after installation, repair or relocation. WSSC doesn't test them; a WSSC-registered journeyman or master plumber with cross-connection certification does. Call the number on this page to be connected with a local plumber in Lanham.

Technician attaching a test kit to a backflow preventer assembly beside a tree-lined commercial building, backflow testing in Lanham, MD

Lanham's setting

Lanham is an unincorporated, fully built-out inner suburb straddling the Capital Beltway beside New Carrollton's Metro and Amtrak station. Neighborhoods like Seabrook sit alongside office buildings, retail along Annapolis Road and Lanham-Severn Road, and medical facilities near Doctors Community Hospital. The median home was built in 1969. Houses from that era almost never had a backflow assembly when they were new, so a residential device here was usually added with a sprinkler system, a boiler or a remodel. Commercial and healthcare buildings are another matter: many have several assemblies, and every testable one needs its yearly test.

Because Lanham is unincorporated, building permits come from Prince George's County DPIE, while WSSC issues and inspects all plumbing permits. The county lists testable backflow devices as one of the few replacements that need a permit. The county's cross-connection line is 301-206-8601.

Rebuild or replace?

FactorRebuildReplace
Body conditionSound, no cracksCracked, pitted or frost-damaged
Age and partsKits still availableParts discontinued
Test resultOne check or relief valve failingRepeated failures after rebuilds
Code fitDevice still right for the hazardHazard changed, such as a new chemical feed
PaperworkRetest after repairWSSC permit, then a test after installation
Call now to be connected with a local plumber in Lanham.
(202) 915-7612

Signs to look for

  • A WSSC test notice for an assembly at your address
  • Water running from an RPZ relief port
  • Low or erratic pressure on the protected line
  • Damage from frost, landscaping equipment or vehicles
  • Equipment changes in a business, such as new boilers or chemical dispensers

Timing and seasonal notes

Residential irrigation assemblies are best tested at spring start-up, and commercial devices are often tested on a fixed date each year so the reports stay current. Winter is the riskiest time for an outdoor assembly; drain it and add an insulated cover before the first hard freeze. Indoor boiler and fire-line devices can be tested any month. If a business near Annapolis Road needs several devices tested, booking them on the same visit keeps the water shutoffs short and the reports filed together. For a house that has changed hands, ask the sellers for the last test report so the new owner knows when the next one is due.

Backflow Testing questions in Lanham

How often does a backflow assembly have to be tested here?
Every testable assembly gets a yearly test, plus a test after installation, repair or relocation. That's WSSC's rule for Lanham properties on its system.
What is the difference between a PVB, a double check and an RPZ?
A PVB guards an irrigation line with one check and an air inlet; a double check uses two checks; an RPZ adds a relief valve between two checks and is used for higher hazards. The device must match what the line feeds.
Does a boiler need backflow protection?
A chemically treated boiler needs protection so the additives can't reach the drinking water, and WSSC lists those among setups with testable assemblies. An untreated system may use a different device.
Why is water dripping or spitting from my backflow device?
Usually a check valve that isn't sealing or a worn relief valve. Water from the relief port means the device is doing its job, but it needs service soon.